NEPS1900 Rack Mounted is a self-contained nitrogen purging system for electronic, optical, high voltage, and laser equipment. It removes humidity and inhibits oxygen, maximising the dry gas purging process for optimal purging operations. The system also has a controlled and dispersed purge gas easily connected to the equipment’s inlet via a single pipe connection. The purge gas is isolated during depressurisation to ensure efficient purging.

Self Contained Nitrogen Purging System

Prominent liquid displays provide constant information and readouts during operation. Easily configure settings and view process control values, including dewpoint measurements in degrees Celsius or Fahrenheit and pressure in Kpa and psi. The dewpoint monitor displays the dryness of the gas before starting the purging operation.

The dewpoint stat feature lets users determine the equipment’s moisture amount before the production control purging procedure. Additionally, the remove dewpoint sensor option monitors the dewpoint dryness progress and automatically switches off and isolates the dry gas when the selected dewpoint is achieved.

Configurable Settings and Process Control Values

The system can be equipped with a data logger that monitors the dewpoint degradation time, allowing the calculation of the water vapour transmission rate (WVTR) and determining the water removal rate during the initial purging phase. It operates from global country voltages and frequencies ranging from 100 to 230 VAC at 50-60 Hz, with a 24VDC version also available.

The NEPS1900 Rack Mounted can be used for various applications such as optical instruments, image intensifiers, thermal imaging, underwater equipment, electronic housings, and surveillance instruments.

  • Fits standard 19-inch racking
  • Easy-to-use Single Connection Purging
  • Dewpoint and Pressure Readout
  • Dewpoint Stat Gas Control
  • Dewpoint display from -80ºC to 20ºC
  • Remote Dewpoint Sensing Option
  • Portable and robust
  • User-programmable
  • Automatic purging operation
  • Maintainable online
  • NATO approved
Useable Gases Air, Nitrogen, SF6, Helium, Argon
Selectable Pressure Ranges 10.3 Kpa (1.5 psi)
17.2 Kpa (2.5 psi)
34.4 Kpa (5.0 psi)
Display Range Pressure 0 to 34.4 Kpa (0-5.0 psi)
Display Range Dewpoint (Selectable)
+20ºC to –80ºC dewpoint
+68ºF to –94ºF dewpoint
Resolution 0.1ºC dewpoint
Accuracy +/- 2ºC dewpoint
Data Output Pressure 0 – 5 Volts
Data Output Dewpoint 0 – 5 Volts
Power 100-230 volt 50-60hz
Power Consumption 3 amps
Dimensions To fit standard 19 inch Racking
Weight 6 kilograms
Operating Temp -10ºC to +50ºC
Storage Temp -50ºC to + 65ºC
Proof Pressure input 136 Kpa (20 PSI)
Flowrate (typical) 20 litres per minute

Nitrogen Enhanced Purging System 1900 Rack Mounted Product Brochure: Download